Max flow rate | 1.38L/H, 1L/H, 2.2L/H, 3.2L/H |
---|
Flow Changes | Flow Rate | Drop spacing (m) | ||||
0.1 | 0.2 | 0.3 | 0.4 | 0.5 | ||
±5% | 1.38L/h | 36 | 51 | 63 | ||
±7.5% | 43 | 59 | 72 | |||
±10% | 52 | 68 | 83 | |||
±5% | 2.2L/h | 63 | 75 | 85 | ||
±7.5% | 74 | 86 | 99 | |||
±10% | 65 | 96 | 119 | |||
±5% | 3.2L/h | 51.0 | 65.0 | 83.0 | ||
±7.5% | 59.0 | 73.0 | 87.0 | |||
±10% | 64.0 | 81.0 | 94.0 | |||
(The inlet pressure is 0.1Mpa. When the ground is flat, different flow lengths are recommended.) |
Flow Rate | Pressure(MPa)VS Flow Rate(L/h) | |||||
0.02 | 0.04 | 0.06 | 0.08 | 0.10 | 0.12 | |
1.38L/h | 0.68 | 0.95 | 1.17 | 1.29 | 1.46 | 1.59 |
2.2L/h | 1.19 | 1.61 | 1.96 | 2.20 | 2.35 | 2.74 |
3.2L/h | 1.70 | 2.32 | 2.77 | 3.13 | 3.32 | 3.66 |
(Recommended work pressure:0.08-0.10Mpa) |